Pengujian Tahanan Konduktor dan Kekuatan Hot Set Isolasi pada Kabel Solar

Main Article Content

Nurmiati Pasra
Samsurizal Samsurizal
Nana Suryana

Abstract

Solar cables are very influential on the safety of Solar Power Plant installations, component damage and fire can occur in installations caused by outer casing dimensions and insulation that do not comply with EN 50396 standards. Conductor resistance that does not meet IEC 60228 standards can cause insulation to break and make cable life shorter. The test results found that VOKSEL type cables have an average value of sheath thickness of 0.90 mm, an average insulation thickness of 0.90 mm and conductor resistance of 4.92? / km, while HENGTONG type cables have an average value of sheath thickness of 0.94 mm, an average insulation thickness of 0.87 mm and a conductor resistance value of 3.20? / km, for APAR-UNICAB type cables have an average value of sheath thickness of 0.88 mm,  The average insulation thickness is 0.85 mm and the conductor resistance value is 5.58 ?/km.  From these tests, VOKSEL &; HENGTONG type cables have met the standards of both EN 50618 standard tests for dimensions &; IEC 60228 for conductor resistance. Meanwhile, APAR-UNICAB type cables have met the EN 50618 standard for solar cable dimensions but have not met IEC 60228 standards based on conductor resistance testing.

Downloads

Download data is not yet available.

Article Details

How to Cite
Pasra, N., Samsurizal, S., & Suryana, N. (2024). Pengujian Tahanan Konduktor dan Kekuatan Hot Set Isolasi pada Kabel Solar. SUTET, 13(2), 120–127. https://doi.org/10.33322/sutet.v13i2.2232
Section
Articles

References

. Anwar Ilmar Ramadhan., Deni Almanda. (2014). Evaluasi Perbandingan Kabel NYM 3 x 1,5mm2 Merk A dan B di Tinjau Dari Tahanan Panas Isolasi Kabelnya. 12(11), 2407-1846.

. Dewi, K. R., & Yuninda, N. H. (2019). Pengaruh peningkatan suhu dan besaran arus terhadap tahanan penghantar kabel listrik tegangan rendah jenis NYM. 4(1), 35-40.

. EN 50618. (2014). Electric Cables For Photovoltaic Systems.

. Ferry Setiawan., Haris Ardianto. (2018). Karakteristik Sifat Mekanis Kekuatan Tarik Komposit Nano Partikel Daur Ulang Pet Dengan Limbah Abu Bagase Boiler. 5(2). 30-44. 2460-1608.

. Hadi Maulana. (2018). Analisis Karakteristik Termal Kabel NYY Untuk Aplikasi Instalasi Listrik Luar Ruangan. 1-47.

. Herman Hasyim., Hersal. (2015). Pengujian Kemampuan Ketahanan Hubung Singkat Isolasi Pada Kabel NYM dan NYM-HY. 1-35.

. Halliday, D dan Resnick, R. (1978). Physics.

. IEC 60228, (1993). Conductors of insulated cables.

. G. F. Moore, Bsc, Phd, FInstP, FIEE (1997). Electric Cables Handbook Third Edition. 97-24044.

. Setiawan, F., & Ardianto, H. (2018). Karakteristik sifat mekanis kekuatan tarik komposit nano partikel daur ulang PET dengan limbah abu bagase boiler. 5(2), 30-44.

. ST. Amina H. Umar, S.Kom.,MT. (2011). Studi Penuaan Akibat Panas Pada Bahan Isolasi Kabel Instalasi Tegangan Rendah. 1-15.

. Syafriudin, (2011). Pengujian Hot Set Kabel N2xsry 12/20 Kv Terhadap Karakteristik Bahan Isolasi. A(1), 21-26.

. Yusuf Fadil Muhamad., Sapto Nisworo., Deria Pravitasari. (2021). Pengujian Tingkat Isolasi Instalasi Listrik Rumah Tinggal. 2747-1217.

Most read articles by the same author(s)

1 2 > >>