Penggunaan Pernafasan Pintar (Smart Breather) Pada Transformator Dibandingkan Dengan Pernafasan Konvensional

Main Article Content

Novi Gusti Pahiyanti
Sigit Sukmajati

Abstract

Savings in using electric fuel in the use of fossil fuel electricity must be reduced. This research was conducted as an effort to save the use of electricity by using solar power plants as the main source, with the making of this research it is hoped that it can be used for electricity consumption at a more economical cost and the use of electric stoves can be used in daily life. The selection of materials and this research can be seen from the existing literature and field studies. Solar power plants in this study use some equipment such as solar panels that by utilizing solar energy will be a source of initial voltage, a regulator control battery as a regulator of electric power charging to the battery (battery), battery (battery) as a storage of electrical power, and an inverter for convert the dc to ac voltage from the battery (battery). The equipment is the main equipment used to turn on the electric stove which is the main burden in this application. This research is expected to be a reference for the use of solar energy for electric stoves in an effort to save electricity. This equipment also refers to the amount of power used on an electric stove of 300 W, with an observation time of 7 hours a day, so that it will produce a current that flows at 6.8 A, and a voltage of 17.3 Volts which occurs at 11.00 WIB . 

Downloads

Download data is not yet available.

Article Details

How to Cite
Pahiyanti, N. G., & Sukmajati, S. (2023). Penggunaan Pernafasan Pintar (Smart Breather) Pada Transformator Dibandingkan Dengan Pernafasan Konvensional. SUTET, 12(2). https://doi.org/10.33322/sutet.v12i2.1668
Section
Articles

References

[1] M. R. Maghami, H. Hizam, C. Gomes, M. A. Radzi, M. I. Rezadad, and S. Hajighorbani. “Power loss due to soiling on solar panel: A review,” Renewable and Sustainable Energy Reviews. 2016.
[2] C. Hachem, P. Fazio, and A. Athienitis, “Solar optimized residential neighborhoods: Evaluation and design methodology,” Sol. Energy, vol. 95, pp. 42–64, 2013.
[3] [M. G. Molina, E. C. Dos Santos, and M. Pacas, “Improved power conditioning system for grid
integration of photovoltaic solar energy conversion systems,” 2010 IEEE/PES Transm. Distrib. Conf. Expo. Lat. Am. T D-LA 2010, pp. 163–170, 2011.
[4] a P. S. Panel and P. Affairs, “Integrating Renewable Electricity on the Grid A Report by theAPS Panel on Public Affairs,” Leadership, 2010.
[5] M. Benghanem, “Optimization of tilt angle for solar panel: Case study for Madinah, Saudi Arabia,” Appl. Energy, 2011.
[6] T. Tudorache and L. Kreindler, “Design of a solar tracker system for PV power plants,” Acta Polytech. Hungarica, 2010.
[7] S. A. Arefifar, F. Paz, and M. Ordonez, “Improving solar power PV plants using multivariate design optimization,” IEEE J. Emerg. Sel. Top. Power Electron., vol. 5, no. 2, pp. 638–650, 2017.
[8] C. Y. Tang, S. Y. Ou, and Y. C. Su, “Design and implementation of a hybrid maximum power point tracker in solar power system,” in Proceedings of the International Conference on Power Electronics and Drive Systems, 2011, pp. 999–1003.
[9] H. Z. Al Garni and A. Awasthi, “Solar PV Power Plants Site Selection: A Review,” in Advances n Renewable Energies and Power Technologies, vol. 1, 2018, pp. 57–75.
[10] L. Miloudi, D. Acheli, and A. Chaib, “Solar tracking with photovoltaic panel,” in EnergyProcedia, 2013.
[11] H. Kang, T. Hong, S. Jung, and M. Lee, “Techno-economic performance analysis of the smart solar photovoltaic blinds considering the photovoltaic panel type and the solar tracking method,” Energy Build., vol. 193, pp. 1–14, 2019.
[12] M. S. Hossain, N. K. Roy, and M. O. Ali, “Modeling of solar photovoltaic system using MATLAB/Simulink,” in 19th International Conference on Computer and Information Technology, ICCIT 2016, 2017, pp. 128–133.
[13] T. Y. Hee and M. M. Isa, “Design of a mini solar power system,” SCOReD2009 -2009 IEEE Student Conf. Res. Dev., no. SCOReD, pp. 300–302, 2009.
[14] D. Karabetsky and V. Sineglazov, “Conceptual Design of Solar Power System,” in 2018IEEE 5th International Conference on Methods and Systems of Navigation and Motion Control, MSNMC 2018 - Proceedings, 2018, pp. 32–35.
[15] C. T. Tsai, Y. B. Muna, H. Y. Lin, C. C. Kuo, and R. Hsiung, “Optimal design and performance analysis of solar power microsystem for mini-grid application,” Microsyst.Technol., 2018.
[16] K. K. McCullough, “Sustainable Residential Development: Planning and Design for Green Neighborhoods,” J. Am. Plan. Assoc., vol. 74, no. 4, pp. 526–527, 2008.
[17] T. Santala, R. Sabol, and B. G. Carbajal, “OPTIMIZED SOLAR MODULE DESIGN.,” Conf Rec IEEE Photovolt. Spec Conf 13th, pp. 733–737, 1978.
[18] G. O. G. Löf and R. A. Tybout, “The design and cost of optimized systems for residential heating and cooling by solar energy,” Sol. Energy, vol. 16, no. 1, pp. 9–18, 1974.
[19] I. Indrianto, M. N. I. Susanti, R. Arianto, and R. Ruli, “Embedded System Practicum Module Design to Increase Student Comprehension of Microcontroller,” TELKOMNIKA, vol. 16, no.1, pp. 53–60, 2018.
[20] R. Ruli A. Siregar, H. Sikumbang, I. B. Sangadji, and Indrianto, “KWh Meter Smart Card Model Token For Electrical Energy Monitoring,” MATEC Web Conf., vol. 218, p. 03002, 2018.
[21] I. Sangadji, Y. Arvio, and Indrianto, “Dynamic Segmentation of Behavior Patterns Based On Quantity Value Movement Using Fuzzy Subtractive Clustering Method,” J. Phys. Conf. Ser., vol. 974, no. 1, 2018.
[22] S. Chanagala and Z. J. Khan, “Energy efficiency,” in Studies in Computational Intelligence, 2019.
[23] G. K. Singh, “Solar power generation by PV (photovoltaic) technology: A review,”Energy. 2013.
[24] S. A. Kalogirou, “Environmental benefits of domestic solar energy systems,” Energy Convers.
Manag., 2004.
[25] M. F. Almi, “Energy Management of Wind/Pv and Battery Hybrid System,” Int. J. New Comput. Archit. their Appl., vol. 4, no. 4, pp. 30–38, 2014.
[26] V. Navasare and R. Yanamshetti, “Voltage Regulation Of Hybrid Wind-Solar Energy System,” vol. 1, no. 4, pp. 243–247, 2014.
[27] Samsurizal, S., & Hadinoto, B. (2020). Studi Analisis Dampak Overload Transformator Terhadap Kualitas Daya Di PT. PLN (Persero) Up3 Pondok Gede. KILAT, 9(1), 136-142.
[28] Panjaitan, susi irmalawati, Mujahidin, M., & Pramana, R. (2012). Studi Pengaruh Beban Lebih Terhadap Kinerja Relai Arus Lebih Pada Transformator Daya (studi kasus transformator daya 1 150/20 kv (30 MVA) di Gardu Induk Batu Besar PT.PLN Batam. Studi Pengaruh Beban Lebih Terhadap Kinerja Relai Arus Lebih Pada Transformator Daya, 1–13.
[29] Pahiyanti, N., Sukmajati, S., & Malik, A. (2021). Nilai Tahanan Kontak Pada PMS BAY Cengkareng Terhadap Rugi Daya Di Gardu Induk Duri Kosambi. SUTET, 11(2), 61 - 70.