Kajian Harmonisa Pada Pemakaian Tenaga Listrik Gedung STT-PLN Jakarta

Main Article Content

Tony Koerniawan
Aas Wasri Hasanah

Abstract

Harmonic is produced by non-linear loads in electrical system. The using of non-linear loads in utility system increaces harmonics in the result sinusoidal waveform of current and voltage can not occur. A harmonic filter is expected to decrease harmonic in STT-PLN electricity consumption  which have current and voltage of harmonic distortion on the threeth. Therefore we need a filter that can reduce the impact of harmonics that occur so as to provide better power quality.

Downloads

Download data is not yet available.

Article Details

How to Cite
Koerniawan, T., & Hasanah, A. W. (2019). Kajian Harmonisa Pada Pemakaian Tenaga Listrik Gedung STT-PLN Jakarta. KILAT, 8(2), 180–189. https://doi.org/10.33322/kilat.v8i2.547
Section
Articles

References

Roger C.Dugan, et al. (2002). Electrical Power System Quality. New York: McGraw Hill.

Rosa, Francisco.D.La. (2006). Harmonics and Power Systems. Missouri:Tailor and Francis.

Sik-Young dan Hanju. (2011). “Single-Tuned Passive Harmonic Filter Design Considering Variances Of Tuning and Quality Factor”. Journal of International Council on Electrical Engineering.1 (1), 7-12.

Soomro, D.M. dan Almelian, M.M. (2015). “Optimal Design Of A Single Tuned Passive Filter to Mitigate Harmonics In Power Frequency”. ARPN Journal of Engineering and applied sciences. 10 (19), 909-9

Jurnal, R. (2019). Analisis Drop Tegangan Pada Jaringan Tegangan Menengah Dengan Menggunakan Simulasi Program Etap. Energi & Kelistrikan, 10(1), 26-37. https://doi.org/10.33322/energi.v10i1.321

Jurnal, R. (2019). Analisa Nilai Saidi Saifi Sebagai Indeks Keandalan Penyediaan Tenaga Listrik Pada Penyulang Cahaya PT. PLN (Persero) Area Ciputat. Energi & Kelistrikan, 10(1), 70-77. Https://Doi.Org/10.33322/Energi.V10i1.330

Siregar RR, Wardana N. Luqman.“. Sistem Monitoring Kinerja Panel Listrik Tenaga Surya Menggunakan Arduino Uno.” JETri J. Ilm. Tek. Elektro. 2017;14(2):81-100.

Handayani, O., Darmana, T., & Widyastuti, C. (2019). Analisis Perbandingan Efisiensi Penyaluran Listrik Antara Penghantar ACSR dan ACCC pada Sistem Transmisi 150kV. Energi & Kelistrikan, 11(1), 37 - 45. https://doi.org/10.33322/energi.v11i1.480

Handayani, O., Darmana, T., & Widyastuti, C. (2019). Analisis Perbandingan Efisiensi Penyaluran Listrik Antara Penghantar ACSR dan ACCC pada Sistem Transmisi 150kV. Energi & Kelistrikan, 11(1), 37 - 45. https://doi.org/10.33322/energi.v11i1.480

Jurnal, R. (2018). Studi Analisis Gangguan Perangkat Hubung Bagi Tegangan Rendah Dan Upaya Mengatasinya Di PLN Area Tanjung Priok. Energi & Kelistrikan, 9(1), 51-59. Https://Doi.Org/10.33322/Energi.V9i1.60

Jurnal, R. (2019). Kajian Sistem Kinerja PLTS Off-Grid 1 Kwp Di STT-PLN. Energi & Kelistrikan, 10(1), 38-44. https://doi.org/10.33322/energi.v10i1.322

Siregar, R. R. A., & Putri, D. R. (2017). Metode Support Vector Machine Pada Klasifikasi Audit Energi: Studi Kasus Gedung STT-PLN Jakarta. Jurnal Informatika dan Komputasi, 8(2), 98-104.

Nisa, T. C., Siregar, R. R. A., & Suliyanti, W. N. (2019). Estimasi Daya Beban Listrik Pada Gardu Induk Cengkareng Dengan Menggunakan Metode TIME Series Model Dekomposisi. TEKNOLOGIA, 2(1)

Hasanah, A., Koerniawan, T., & Yuliansyah, Y. (2019). Kajian Ketelitian Current Transformer (CT) Terhadap Kesalahan Rasio Arus pada Pelanggan 197 kVA. Energi & Kelistrikan, 11(1), 9 - 16. https://doi.org/10.33322/energi.v11i1.390

Hasanah, A., Hariyati, R., & Qosim, M. (2019). Konsep Fotovoltaik Terintegrasi On Grid dengan Gedung STT-PLN. Energi & Kelistrikan, 11(1), 17 - 26. https://doi.org/10.33322/energi.v11i1.394