Prediksi Sisa Umur Generator Dengan Metode Pengujian Dielektrik Pada Stator Generator Unit 2 PLTU Ombilin

Main Article Content

Alex Fernandes
Samsurizal Samsurizal

Abstract

Electrical demand getting higher every year, therefore reliability is needed in distributing electrical energy to consumers, to realize this reliability, electrical equipment that can work properly is needed so that there are no obstacles in the operating system, one of the electrical equipment that has a very important role very important in a steam power plant is the generator, along with the age of use of the generator which has been more than 20 years at the Ombilin PLTU, there must be some obstacles including its isolation which can cause current leakage and total damage to the generator. The purpose of the dielectric test. This research was conducted to predict the remaining life of the generator due to dielectric problems that occur in the insulation system by conducting dielectric tests and finding solutions to extend the life of the generator. The method used in this study using the D-MAP method with the formula used from the values obtained in dielectric testing, such as tan delta testing, leakage current testing, and partial discharge testing. The results of this dielectric test get a breakdown voltage of 42.48% and get a prediction of the remaining life of the generator for another 4 years. And to improve the breakdown voltage value, a revarnish is carried out to improve the partial discharge value.

Downloads

Download data is not yet available.

Article Details

How to Cite
Fernandes, A., & Samsurizal, S. (2023). Prediksi Sisa Umur Generator Dengan Metode Pengujian Dielektrik Pada Stator Generator Unit 2 PLTU Ombilin. KILAT, 12(1), 10–19. Retrieved from https://jurnal.itpln.ac.id/kilat/article/view/1994
Section
Articles

References

Afandi, Robin (2016), “Evaluasi Pengukuran Tahanan Isolasi Pada Sisi Output Generator Wescan Unit 1 di PT. PLN (Persero) Pembangkit Sumbangsel Sektor Pembangkit Keramasa”, Politeknik Negeri Sriwijaya.

Amir, Mohammad., & Julian, I Wayan Angga (2018) “Analisa Pengaruh Partial discharge Dan Tan ? Terhadap Umur Isolasi Belitan Stator Akibat Ikatan Kumparan Generator Longgar”, Institut Sains Teknologi Nasional.

Arismunandar, A., (2001) Teknik Tegangan Tinggi, Pradnya Paramita, Jakarta.

Januarizki, Dery (2017) yang berjudul “analisis pengujian tahanan isolasi generator Unit 2

PT. PJB UBJ O & M PLTU 1 Pacitan Jawa Timur Dengan Metode Tan Delta” Universitas Muhammdiyah Yogyakarta.

Julian, I Wayan Angga (2018) yang berjudul “Analisa Pengaruh Partial discharge Dan Tan Akibat Ikatan Longgar Pada Kumparan Generator Terhadap Umur Isolasi Belitan Stator” Institut Sains Dan Teknologi Nasional

Handojo, Sigit Pudji. (2015). Analisa Penerapan Jembatan Schering Pada Alat Ukur Bahan Isolasi. Jakarta : Institut Sains dan Teknologi Nasional

Husnul, Muhammad., (2008), Deteksi dan Analisis Peluahan Parsial pada Belitan Stator Generator., FTUI., Jakarta.

IEEE Std 286-2000, IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation.

IEEE Guide for Insulation Maintenance of Electric Machines, 2016. IEEE Power and Energi Society, New York

Afrianda, R., Samsurizal, S., & Nurul, A. A. (2020). Pengaruh Ketidakseimbangan Beban Terhadap Efesiensi Transformator Distribusi Studi Gardu PT PLN (PERSERO) Area Bekasi. SUTET, 10(1), 29-38.

Syakur, Abdul, (2009) Teori dan Hasil Eksperimen Partial discharge Pada Bahan isolasi, BP UNDIP, Semarang,

Samsurizal, S., & Hadinoto, B. (2020). Studi Analisis Dampak Overload Transformator Terhadap Kualitas Daya Di PT. PLN (Persero) Up3 Pondok Gede. KILAT, 9(1), 136-142.