Evaluasi Nilai Setting Rele Jarak Sebagai Proteksi Saluran Udara Tegangan Tinggi 150 KV Menggunakan DigSilent Power Factor

Main Article Content

Ibnu Hajar
Muhammad Jafar Shodik

Abstract

The electric power system is a complex system, it needs to be maintained so the system can run optimally. Many factors can interference the transmission and distribution system process from sources (power plant) to consumers. In order to maintain the reliability and security of the transmission line, a protection system is needed. The protection system must work in its working area and not overlaping each other. The protection system that commonly used to secure the transmission line is distance relay. The working principle of the distance relay is sensing the impedance and dividing the impedance into several zones so the relay can works simultinously with other relays. This study uses a quantitative method to collect data, simulate them, and compare the relay setting result with IEEE Standard. In this case, the result of the calculation of the zone impedance value in zone-1 is 2.562 ohms, zone-2 is 4.611 ohms and zone-3 is 7.852 ohms. The simulation results show that these settings correspond with the IEEE C37.113.2015 standard and work selectively in their respective zones.

Downloads

Download data is not yet available.

Article Details

How to Cite
Hajar, I., & Shodik, M. J. (2024). Evaluasi Nilai Setting Rele Jarak Sebagai Proteksi Saluran Udara Tegangan Tinggi 150 KV Menggunakan DigSilent Power Factor. SUTET, 14(1), 1–13. Retrieved from http://jurnal.itpln.ac.id/sutet/article/view/2291
Section
Articles

References

R. A. Duyo, “Analisis Penyebab Gangguan Jaringan Pada Distribusi Listrik Menggunakan Metode Fault Tree Analysis di PT. PLN (Persero) Rayon Daya Makassar,” Vertex Elektro, vol. 12, no. 02, pp. 1-12, 2020.

W. Setiawan, R. A. Murdiantoro dan Nasrulloh, “Analisis Keandalan Sistem Distribusi Tenaga Listrik Akibat Gangguan Pada Masa Pandemi Covid-19 di PT. PLN (Persero) ULP Sidareja,” Journal of Electronic and Electrical Power Application, pp. 36-42, 2021.

I. Hajar dan M. H. Pratama, “Analisa Nilai SAIDI SAIFI Sebagai Indeks Keandalan Penyediaan Tenaga Listrik Pada Penyulang Cahaya PT. PLN (Persero) Area Ciputat,” Energi & Kelistrikan, vol. 10, no. 1, pp. 70-77, 2018.

Z. Zulkarnaini dan M. Rizki, “Studi Koordinasi Rele Proteksi Pada Saluran Udara Tegangan Tinggi 150 kV GI Payakumbuh-GI Koto Panjang,” dalam PIMIMD, Padang, 2017.

A. Srinaldi, Muliadi, Syukri, M. R. Azmi dan Husaini, “Proteksi Jaringan Transmisi Saluran Udara Dengan Menggunakan Relay Jarak,” Aceh Journal of Electrical Engineering and Technology (AJEETECH), vol. 1, no. 1, pp. 6-11, 2021.

H. Abibie, Sulistyowati dan F. Ronilaya, “Kajian Koordinasi Sistem Proteksi Pada Sistem Transmisi 70 kV GI Banaran Kediri Transmission Line Bay Pare,” ELPOSYS: Jurnal Sistem Kelistrikan, vol. 7, no. 3, pp. 51-57, 2020.

M. M. Ostojic dan Z. N. Stojanovic, “An algorithm for distance protection based on the change of the voltage phase angle,” Electric Power System Research, vol. 223, no. 109674, 2023.

M. W. Aminullah dan D. U. Y. Wardhani, “Pengaruh Pengaturan Rele Jarak Terhadap Proteksi Utama Pada Penghantar SUTET 500kV,” Jurnal Ampere, vol. 7, no. 2, pp. 108-115, 2022.

M. Zainuddin dan Suherman, “Setting Koordinasi Proteksi Distance Relay Pada Saluran Transmisi 150 kV Gardu Induk Isimu Ke Gardu Induk Botupingge PT. PLN (Persero) Sistem Gorontalo,” Radial - juRnal perADaban saIns, rekayAsa dan teknoLogi, vol. 1, no. 2, pp. 78-89.

A. Jamaah, “Evaluasi Setting Rele Jarak Gardu Induk Ungaran Jaringan 150 kV Arah Krapyak-2,” ORBITH, vol. 10, no. 1, pp. 82-89, 2014.

R. A. Wahyuningsih, Supriyatna dan A. B. Muljono, “Proteksi Rele Jarak (Distance Relay) Pada Saluran Udara Tegangan Tinggi (SUTT) 150 kV Sistem Kelistrikan Lombok,” Dielektrika, vol. 7, no. 1, pp. 15-24, 2020.

I. A. Fauzi dan H. S. Dini, “Koordinasi Rele Jarak Sebagai Pengaman Utama Dengan Rele Arus Lebih Pada Saluran Udara Tegangan Tinggi 150 kV Balongbendo - 150 kV Sekarputih,” KILAT, vol. 11, no. 1, pp. 40-52, 2022.

A. S. Sampeallo, Nursalim dan M. A. S. Sagho, “Evaluasi Penyetelan Rele Jarak Pada Jaringan Transmisi 70 kV Bolok - Maulafa Menggunakan DigSilent 15.1.7,” Jurnal Media Elektro, vol. 9, no. 1, pp. 1-9, 2020.

T. I. Yusuf dan L. M. Taslan, “Setting Distance Relay Pada Jaringan Transmisi 150 kV Sistem Gorontalo,” JURNAL TEKNIK, vol. 16, no. 1, pp. 81-92, 2018.

A. S. Sampeallo, Nursalim, J. F. Mandala dan M. A. S. Sagho, “Effect of distance relay settings on interference zone reading on 70 kV transmission lines Bolok - Maulafa using digsilent 15.1.7,” Journal Physics: Conference Series, vol. 012014, 2021.

L. Andreansyah, Gunawan dan B. Sukoco, “Analisis Relai Jarak Sebagai Proteksi Pada Jaringan Transmisi Saluran Udara Tegangan Tinggi 150 kV Gardu Induk Randu Garut - Weleri,” dalam Konferensi Ilmiah Mahasiswa Unissula (KIMU) 2, Semarang, 2019.

S. Seghir, T. Bouthiba, R. Boukhari, S. Dadda dan A. H. Bouricha, “Fault Resistance Effect On Distance Protection in High Voltage Transmission Lines,” dalam The Internation Conference on Recent Advances in Electrical Systems, Tunisia, 2017.