Gangguan Hubung Singkat Gas SO2 Terhadap Gas SF6 PMT 150 kV di GI Duri Kosambi

Main Article Content

Novi Gusti Pahiyanti

Abstract

The decrease in the quality of SF6 gas is caused by the influence of temperature, the use of SF6 gas and the presence of particles of chemical compounds. In testing the quality of SF6 gas, the parameters obtained are purity, dew point, moisture content and SO2. SF6 gas as an insulating medium in PMT150KV that is still effective with a high dielectric factor. So that when a short circuit occurs in PMT 150KV SF6 gas as an insulating medium can extinguish the electric arc rate, good quality is needed. In testing the quality of SF6 gas, there is a product decompose or SO2 on Duri Kosambi substation in phase R valued at 150 phase, phase S valued at 140 and phase T valued at 157 whose values exceed the standard limits of the Gas Insulated Substation (GIS) Maintenance Manual and IEC 60480 with a standard value of 12 ppmv. This study aims to analyze the effect of short circuit interference and SO2 gas on SF6 gas quality at PMT 150KV. In GI Duri Kosambi, the value of short-circuit fault currents affecting SF6 gas and SO2 gas affects the quality of SF6 gas such as purity, dew point and moisture content. Then it is necessary to reclaim SF6 gas or replace new SF6 gas.

Downloads

Download data is not yet available.

Article Details

How to Cite
Pahiyanti, N. G. (2024). Gangguan Hubung Singkat Gas SO2 Terhadap Gas SF6 PMT 150 kV di GI Duri Kosambi. SUTET, 13(2), 91–100. https://doi.org/10.33322/sutet.v13i2.2210
Section
Articles

References

Santoso, B. B., & Bangsa, I. A. (2021). Analisa Pengujian Kualitas Gas SF6 Pada Pemutus Tenaga (PMT) 66 KV Bay Reaktor 4R2 di GITET Bandung Selatan. Universitas Singaperbangsa Karawang, Karawang.

Aribowo, D., Permata, E., Desmira, Ekawati, R., & Bahtiar, K. (2018). Analisis Hasil Uji PMT 150kV Pada Gardu.

Damiri, D., & Prasetio. (2021). Redesign Gas Insulated Switchgear to Semi Air Insulated Switchgear 500 kV side and 150 kV side in EHVS Kembangan.

Darwis, & Bahri, B. Z. (2015). analisis kapasitas dan momentry pada pemutus tenaga (pmt) gas sf6 di gardu induk 150 kv tello. Makasar, Indonesian.

Enrico, F. X., & hidayat. (2018). Analisa Kualitas Gas SF6 Sebagai Media Isolasi Pada GIS Lontar.

Fadli, Y., & Samsurizal. (2021). Relokasi Recloser Dengan Metode Section Technique Pada Jaringan Distribusi 20 kV.

Farzi, A., Irawan, D., & Astutik, R. P. (2021, january). Analisis kinerja circuit breaker 20 kv plta wonorejo bermedia sf6 (sulphur hexaflouride) . Universitas Muhammadiyah Gresik, Jawa Timur, Indonesia.

Fauzi, I., & Dini, H. (2022). Koordinasi Rele Jarak Sebagai Pengaman Utama Dengan Rele Arus Lebih Pada Saluran Udara Tegangan Tinggi 150 Kv Balongbendo - 150 Kv Sekarputih.

Fauziah, F., & Karhab, R. S. (2019). Pelatihan Pengolahan Data Menggunakan Aplikasi. Kalimantan Timur, indonesia.

Goeritno, A., Rasiman, S., & Komara, Z. (2018, oktober). Kinerja Pemutus Tenaga Tegangan Tinggi Bermedia Gas SF 6 Berdasarkan Sejumlah Parameter Diri. indonesia.

Harunanda, P., & fauziah, D. (2021). Analisis Pengaruh Tekanan Gas SF6 tehadap Laju Busur Listrik pada PMT diGardu Induk Cilegon PT PLN (Persero) Transmisi Jawa Bagian Barat.

Haryudo, S. I., Kholis, N., & Kartini. (2021). analisis hubung singkat pada sistem distribusi 20 kv pt. pertamina ep asset 4 field cepu distrik ledok menggunakan etap 12.6.0. surabaya, Indonesia .

Hasyim, M., & Listiawan, T. (2014). Penerapan aplikasi ibm spss untuk analisis data bagi pengajar pondok hidayatul mubtadi'in ngunut tulungagung demi meningkatkan kualitas pembelajaran dan kreativitas karya ilmiah guru. tulung agung, indonesia.

Nurjannah, D. S., Santoso, D. B., & Bangsa, I. A. (2021). Analisa Pengujian Kualitas Gas SF6 Pada Pemutus Tenaga (PMT) 66 KV Bay Reaktor 4R2 di GITET Bandung Selatan. Universitas Singaperbangsa Karawang, karawang, indonesia.

PT PLN (Persero). (2010). Buku Petunjuk Batasan Operasi Dan Pemeliharaan Penyaluran Tenaga Listrik Pemutus Tenaga.