Analisis Sistem Pencahayaan Pada Lantai 3 Gedung Kuliah Umum Institut Teknologi Sumatera

Main Article Content

Khoirun Naimah
Abri Rahmatullah
M Azzam As Tsabit
Muqqafa Akbar P
Kamilah
Javeni Eysama Lumban G
Nuril Hidayat
M Allezandro Alghozi
Reuben Damara
Aldhi S
Ardian S

Abstract

Various regulations and standards have been issued by various authorities to support and increase the efficiency of energy use and manage energy conservation activities. Energy conservation is the obligation of all parties, including from the side of energy users in buildings, including one of them is the ITERA Public Lecture Building which is used mostly for classrooms, but there is no data on the quality of the lighting system. Therefore, this study aims to analyze the lighting system (energy consumption and lighting level) on the 3rd Floor of the ITERA General Lecture Building using the energy audit method. From the results of the study, it was found that the total energy consumption in the artificial lighting system (lamps) was 798.72 kWh/month, and the lighting level met the minimum limits of SNI 6197-2020, but out of 11 classrooms there were 7 rooms that were too much larger than SNI 6197-2020. So that the saving opportunity that can be done is to change the awareness of room energy users by reducing the length of time the lamp is used and prioritizing the use of natural light in the morning and afternoon so that it can save energy use by up to 34%.

Downloads

Download data is not yet available.

Article Details

How to Cite
Naimah, K., Rahmatullah, A., As Tsabit, M. A., Akbar P, M., Kamilah, Lumban G, J. E., Hidayat, N., Alghozi, M. A., Damara, R., S, A., & S, A. (2023). Analisis Sistem Pencahayaan Pada Lantai 3 Gedung Kuliah Umum Institut Teknologi Sumatera. ENERGI & KELISTRIKAN, 15(1), 24–30. https://doi.org/10.33322/energi.v15i1.1978
Section
Articles

References

Inpres No. 13 Tahun 2011 tentang Penghematan Energi dan Air.

Perpres No. 11 Tahun 2023 tentang Urusan Pemerintahan Konkruen Tambahan di Bidang Energi dan Sumber Daya Mineral pada Subbidang Energi Baru Terbarukan.

Peraturan Pemerintah No.70 Tahun 2009 tentang Konservasi Energi.

SNI-ISO 50002 tentang prosedur audit energi.

Maidina, “Pengaruh Aspek Energy Efficiency and Conservation Terhadap Biaya Konstruksi Green Building Dibandingkan Dengan Conventional Building,” 2012.

BPPT, Indonesia Energy Outlook 2018: Sustainable Energy for Land Transportation, Jakarta: BPPT, 2018.

Naimah, Khoirun. "ANALISA KONSUMSI ENERGI DAN SISTEM PENCAHAYAAN GEDUNG C INSTITUT TEKNOLOGI SUMATERA." Journal of Energy and Electrical Engineering (JEEE) 2, no. 2. 2021.

BSN. SNI 6197-2020 tentang Konservasi Energi Pada Sistem Pencahayaan, Jakarta:BSN, 2020.

Setiati, Tri Woro, and Dyah Utari Yusa Wardhani. "Evaluasi Kenyamanan Visual Pada Ruang Kuliah Non-Konvensional (Studi Kasus: Ruang Kuliah di Menara Universitas Tridinanti Palembang)." Arsir 4, no. 1, pp 1-8. 2020.

Prasetia, Vicky. "Evaluasi Sistem Pencahayaan Gedung Pendidikan Perkuliahan Sesuai Standar Nasional Indonesia (SNI)." Infotekmesin 13, no. 2, pp 308-313.2022.

F. T. Kresnadi, “Evaluasi Penggunaan Listrik dengan Metode Konservasi Energi untuk Efisiensi Energi di Gedung FKIP UNTIRTA”, energi, vol. 12, no. 1, pp. 11–21, Jun. 2020.

Prasetyo SS, Kusumarini Y. “Studi Efisiensi dan Konservasi Energi Pada Interior Gedung P Universitas Kristen Petra”. Intra. 4(1):36-45. Jan 2016.

A. A. Rahmawati and S. Abduh, “Audit Energi Gedung Kampus A Universitas Muhammadiyah Tangerang untuk Penerapan Sistem Manajemen Energi Berbasis ISO 50001:2018”, energi, vol. 14, no. 2, pp. 187–195, Jan. 2023.

Sunardiyo, Said. "Implementation of Standard Operating Procedures in the Energy Efficiency and Conservation Campus for Suppressing Effect Greenhouse Gas Emissions." 2014.

Yola, Octaviani Asri. "Studi Perilaku Konsumsi Energi Listrik Di Universitas Andalas." PhD diss., Universitas Andalas, 2020.